.Ok_Ä.Ok_äOperating Instructions EN3200 C E32GAC... IPC 3241 C
Safety instructionsGeneral safety information2 10Lenze ¯ BA_3241C ¯ 4.0Maintenance and servicing¯ The components are maintenance−free if the req
Safety instructionsProduct−specific safety instructions2 11Lenze ¯ BA_3241C ¯ 4.0 2.2 Product−specific safety instructions ¯ The device is class
Safety instructionsSafety instructions for the installation according to UL/CSA2 12Lenze ¯ BA_3241C ¯ 4.0 2.3 Safety instructions for the instal
Safety instructionsSafety instructions for the installation according to UL/CSA2 13Lenze ¯ BA_3241C ¯ 4.0 HomologationUnderwriter Laboratories
Safety instructionsResidual hazards2 14Lenze ¯ BA_3241C ¯ 4.0 2.4 Residual hazards Danger!Hot surface during operationThe heatsink at the back
Product descriptionScope of supply3 15Lenze ¯ BA_3241C ¯ 4.03 Product descriptionI/O System 1000EPM-S701IPC 3241 C32xxC_005Fig. 3−1 IPC 3241 C w
Product descriptionApplication as directed3 16Lenze ¯ BA_3241C ¯ 4.0 3.2 Application as directed The IPC is used as directed if it is solely us
Product descriptionDevice features3 17Lenze ¯ BA_3241C ¯ 4.0 3.3 Device featuresRange IPC 3241 CDesign ¯ Mounting on standard DIN rail (35 mm)¯
Product descriptionIdentification3 18Lenze ¯ BA_3241C ¯ 4.0 3.4 IdentificationInput:HW: SW:Type:32xxC_002Fig. 3−2 TypenschildPos. Descrip
Product descriptionControls and displays3 19Lenze ¯ BA_3241C ¯ 4.0 3.5 Controls and displays0451132632xxC−001Fig. 3−3 Control and display elemen
Please read these instructions before you start working!Follow the enclosed safety instructions. Tip!Information and tools concerning the Lenze pro
Product descriptionControls and displays3 20Lenze ¯ BA_3241C ¯ 4.0 LED status displays LEDInterval MeaningColor 1 / Color 2PowerGreen Is ONcons
Product descriptionUPS functionality3 21Lenze ¯ BA_3241C ¯ 4.0 3.6 UPS functionalityIn case of supply voltage failure, the UPS functionality (un
Technical dataGeneral data and operating conditions4 22Lenze ¯ BA_3241C ¯ 4.04 Technical data4.1 General data and operating conditions General
Technical dataMechanical data4 23Lenze ¯ BA_3241C ¯ 4.0 Operating conditionsAmbient conditionsClimaticStorage/transport EN 60721−3−2 2K3: −25 ..
Mechanical installationImportant notes5 24Lenze ¯ BA_3241C ¯ 4.05 Mechanical installation5.1 Important notes Danger!Hot surface during operatio
Mechanical installationDimensions5 25Lenze ¯ BA_3241C ¯ 4.0 5.2 Dimensions136 mm112 mm105 mm150 mm100 mm35 mm32xxC_001 32xxC_003Fig. 5−1 Dimensi
Mechanical installationMounting5 26Lenze ¯ BA_3241C ¯ 4.0 5.3 Mounting Stop!Short circuit on the backplane bus contactThe backplane bus signals
Mechanical installationDismounting5 27Lenze ¯ BA_3241C ¯ 4.0 5.4 Dismounting Danger!Hot surface during operationThe heatsink at the back of the
Electrical installationImportant notes6 28Lenze ¯ BA_3241C ¯ 4.06 Electrical installation6.1 Important notesThe installation must be carried out
Electrical installationEMC−compliant wiring6 29Lenze ¯ BA_3241C ¯ 4.0 6.2 EMC−compliant wiringNotes on EMC−compliant wiringGeneral notes ¯ The e
Contents i 3Lenze ¯ BA_3241C ¯ 4.01 About this documentation 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical installationConnecting voltage supply (24 V)Connection plan6 30Lenze ¯ BA_3241C ¯ 4.0 6.3 Connecting voltage supply (24 V) Stop!No d
Electrical installationInterfaces for peripheral devicesUPS connection6 31Lenze ¯ BA_3241C ¯ 4.0 6.4 Interfaces for peripheral devices6.4.1 UPS
Electrical installationInterfaces for peripheral devicesEthernet interface6 32Lenze ¯ BA_3241C ¯ 4.0 6.4.3 Ethernet interfaceFigure Connection C
Electrical installationInterfaces for peripheral devicesUSB interface6 33Lenze ¯ BA_3241C ¯ 4.0 6.4.4 USB interfaceFigure Connection Connection
MaintenanceRegular checks7 34Lenze ¯ BA_3241C ¯ 4.07 Maintenance7.1 Regular checksThe system is maintenance−free. Nevertheless, visual inspectio
MaintenanceExchanging GapPad strips7 35Lenze ¯ BA_3241C ¯ 4.0 7.3 Exchanging GapPad strips Note!On the rear of the device, there are two GapPad
Index836Lenze ¯ BA_3241C ¯ 4.08 Index0 ... 924 V connection, 30AAir humidity, 23Ambient conditions− Climatic, 23− Mechanical, 23− Site altit
Index 837Lenze ¯ BA_3241C ¯ 4.0NNameplate, 18Noise immunity, 22Notes, definition, 7Notes on EMC−compliant wiring,29Notes on mounting, 24OOpe
© 07/2014 | BA_3241C | .Ok_ | 4.0 | TD17 Lenze Automation GmbHPostfach 10 13 52, D−31763 HamelnHans−Lenze−Str. 1, D−31855 AerzenGermany+495154
Contentsi 4Lenze ¯ BA_3241C ¯ 4.06 Electrical installation 28. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
About this documentationDocument history1 5Lenze ¯ BA_3241C ¯ 4.00Fig. 0Tab. 01 About this documentationContentsThis documentation provides info
About this documentationConventions used1 6Lenze ¯ BA_3241C ¯ 4.0 1.2 Conventions usedThis documentation uses the following conventions to disti
About this documentationNotes used1 7Lenze ¯ BA_3241C ¯ 4.0 1.3 Notes usedThe following pictographs and signal words are used in this documentat
Safety instructionsGeneral safety information2 8Lenze ¯ BA_3241C ¯ 4.02 Safety instructions2.1 General safety informationScopeThe following gene
Safety instructionsGeneral safety information2 9Lenze ¯ BA_3241C ¯ 4.0Mechanical installation¯ Install the product according to the regulations