EDS94TA10040xxxx EN 1.1 - 10/2008 L 63
9400 Technology applications | Synchronism with mark synchronisation
Parameter setting & configuration
Parameterisable function blocks
4.14.15 LimitTPDiffShaft
4.14.16 LimitTPDiffTool
Is an instance of Function
L_SdSetPosition Mark synchronisation (master value):
Conversion of the TP limit selected in the real units of the machine via C03651 into
a position in [increments].
Mark synchronisation (master value)
(C 34)
Parameter Possible settings Information
C03651 -214000.0000 unit 214000.0000 Position value
• Initialisation: 0.0000 unit
C03652 String of digits Position unit
•Read only
C03653 -2147483647 2147483647 Status
•Read only
Is an instance of Function
L_SdSetPosition Mark synchronisation (setpoint):
Conversion of the TP limit selected in the real units of the machine via C03851 into
a position in [increments].
Mark synchronisation (setpoint)
(C 39)
Parameter Possible settings Information
C03851 -214000.0000 unit 214000.0000 Position value
• Initialisation: 0.0000 unit
C03852 String of digits Position unit
•Read only
C03853 -2147483647 2147483647 Status
•Read only