Installation
UONu_^MPMQ 4-13
L
4.2.3.2 Assignment of the control terminals
hPRKMMOS
6 2
7
8
9
K 1 1
K 1 2
K 1 4
2 0
2 8
E 1
E 2
E 3
E 4
3 9
P
o
ec
ion agains
con
ac
D The control terminals have basic isolation (single insulating distance).
D If protection against contact is required,
- a double insulating distance must be available.
- the components to be conncted must provide the second insulating
distance.
Protection against polarity reversal
The protection against polarity reversal prevents the wrong c onnection of
the internal control inputs. It is however possible to overcome the protec-
tion against polarity reversal by applying great force.
cfd QJT mçëáíáçå çÑ íÜÉ Åçåíêçä íÉêãáå~äë
Terminal Use
(Factory setting is printed in bold)
Level Data
Analog
7 GND 1
inputs
8 Setpoint input,
reference:
Terminal 7
(0 to 10V)
6
4
2
5
3
1
5-6
5-6
3-4
1-2
0to20mA
4to20mA
0to5V
1
V
Resolution: 10 bit
Linearity fault:
±0.5 %
Temperature fault: 0.3 % (0...+40
°C)
Input resistance
Voltage s ignal: > 100 k
Ω
Jumper
urrent signal: 250 Ω
9 Supply for setpoint potentiometer 5.2V / 6mA
Analog
output
62 Analog output, reference: terminal 7
(Field frequency)
0... 6 V /
2mA
Resolution: 10 bit
Digital
inputs
20 Voltage supply for digital inputs
15 V/20 mA
28 Controller enable HIGH
HIGH: 12 V ... 30 V
E4 CW rotation/
CCW rotation (CW/CCW)
CW: LOW
CCW: HIGH
LOW:0V...3V
E3 DC-injection brake HIGH
E2
JOG frequencies
Binary code
E1
20Hz, 30Hz, 40Hz
39 GND 2 (reference for external voltages)
Terminal Use
(Factory setting is printed in bold)
Relay position
(switched)
Data
Relay
output
K11 Relay output normally-closed contact
(TRIP)
opened
24 V AC / 3,0 A or
60 V DC / 0.5 A
K1
K12 Relay mid-position contact
K14 Relay output normally-open contact
(TRIP)
closed