EDS82ZAFVCxxx.IFõÄ.IFõäCommunication ManualDeviceNet lE82ZAFVC001 / E82ZAFVC010Function module L−force Communication
Product descriptionApplication as directed3 l 10EDS82ZAFVCxxx EN 4.03 Product description3.1 Application as directed The E82ZAFVC001 function m
Product descriptionIdentification3 l 11EDS82ZAFVCxxx EN 4.0 3.2 IdentificationE82AF000P0B201XXAPPLICATION010 / 3A22A22A22APPLICATION010 / 3
Product descriptionProduct features3 l 12EDS82ZAFVCxxx EN 4.03.3 Product featuresThe E82ZAFVC0xx function module (DeviceNet / DeviceNet PT) conn
Product descriptionConnections and interfaces3 l 13EDS82ZAFVCxxx EN 4.03.4 Connections and interfacesFunction module E82ZAFVC001E82ZAFV001EPos
Product descriptionConnections and interfaces3 l 14EDS82ZAFVCxxx EN 4.0 Function module E82ZAFVC010E82ZAFD101APos. Description Detailedinformati
Technical dataGeneral data4 l 15EDS82ZAFVCxxx EN 4.04 Technical data4.1 General data Field ValuesCommunication profile DeviceNetCommunication
Technical dataProtective insulation4 l 16EDS82ZAFVCxxx EN 4.0 4.3 Protective insulation{ Danger!Dangerous electrical voltageIf Lenze controllers
Technical dataConnection terminals4 l 17EDS82ZAFVCxxx EN 4.0 4.4 Connection terminals E82ZAFVC001 function moduleX3/V+External DC voltage sup
Technical dataCommunication time4 l 18EDS82ZAFVCxxx EN 4.0 4.5 Communication timeThe communication time is the time between the start of a reque
Technical dataDimensions4 l 19EDS82ZAFVCxxx EN 4.0 4.6 DimensionsE82ZAFVC001 function moduleE82ZAFD001Ea51 mmb 64 mmc 15 mmE82ZAFVC010 funct
Contentsi l 2EDS82ZAFVCxxx EN 4.01 About this documentation 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
InstallationMechanical installationWiring according to EMC (CE−typical drive system)5 l 20EDS82ZAFVCxxx EN 4.05 Installation} Danger!Inappropria
InstallationElectrical installationWiring with a host (master)5 l 21EDS82ZAFVCxxx EN 4.0 5.2.2 Wiring with a host (master)The following figure
InstallationElectrical installationWiring with a host (master)5 l 22EDS82ZAFVCxxx EN 4.0Properties of the "Thick Cable" in accordance
InstallationElectrical installationWiring with a host (master)5 l 23EDS82ZAFVCxxx EN 4.0Features of the data lineInsulation diameter 1.96 mm (
InstallationElectrical installationVoltage supply5 l 24EDS82ZAFVCxxx EN 4.0 5.2.3 Voltage supply ) Note!DeviceNet communication modules from Le
InstallationElectrical installationTerminal assignment5 l 25EDS82ZAFVCxxx EN 4.0 5.2.4 Terminal assignment Function module E82ZAFVC001Supply
InstallationElectrical installationTerminal assignment5 l 26EDS82ZAFVCxxx EN 4.0 Function module E82ZAFVC010Controller inhibit (CINH) supply via
InstallationElectrical installationCable cross−sections and screw−tightening torques5 l 27EDS82ZAFVCxxx EN 4.0 5.2.5 Cable cross−sections and
InstallationElectrical installationBus cable length5 l 28EDS82ZAFVCxxx EN 4.0 5.2.6 Bus cable length Depending on the baud rate and the cable
CommissioningBefore switching on6 l 29EDS82ZAFVCxxx EN 4.06 Commissioning During commissioning, system−dependent data as e.g. motor parameter
Contents i l 3EDS82ZAFVCxxx EN 4.07 Diagnostics 34 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CommissioningCommissioning steps6 l 30EDS82ZAFVCxxx EN 4.0Step Procedure see1. If necessary, set the software compatibility^ 312. Set the node
CommissioningControls and displaysPossible settings using the front switch6 l 31EDS82ZAFVCxxx EN 4.06.3 Controls and displays6.3.1 Possible se
CommissioningControls and displaysPossible settings using the front switch6 l 32EDS82ZAFVCxxx EN 4.0Setting of the device address) Note!The devi
CommissioningControls and displaysPossible settings using the front switch6 l 33EDS82ZAFVCxxx EN 4.0 Baud rate setting) Note!The baud rate mus
DiagnosticsLED status displays7 l 34EDS82ZAFVCxxx EN 4.07 Diagnostics7.1 LED status displays Function module E82ZAFVC001 Function module E82ZAF
DiagnosticsLED status displays7 l 35EDS82ZAFVCxxx EN 4.0Protection against uncontrolled restart) Note!Establishing communicationIf communicat
DiagnosticsTroubleshooting and fault elimination7 l 36EDS82ZAFVCxxx EN 4.0 7.2 Troubleshooting and fault eliminationNo communication with the co
Codes 8 l 37EDS82ZAFVCxxx EN 4.08 CodesHow to read the code tableColumn MeaningCode(Lenze) codel The parameters of a configurable code marked
Codes8 l 38EDS82ZAFVCxxx EN 4.0 C0002: Parameter set management(extract from code table)Code SubcodePossible settingsData typeLenze SelectionC00
Codes 8 l 39EDS82ZAFVCxxx EN 4.0Transmitting the parameter sets with the keypad:Selection ImportantUsing the keypad, you can transmit the para
About this documentation1 l 4EDS82ZAFVCxxx EN 4.00Fig. 0Tab. 01 About this documentationContentsThis documentation exclusively contains descript
Codes8 l 40EDS82ZAFVCxxx EN 4.0 C1500: Software product codeCode SubcodePossible settingsData typeLenze SelectionC1500 − g − VSThe code contains
Codes 8 l 41EDS82ZAFVCxxx EN 4.0 C1510:Configuration of process input dataCode SubcodePossible settingsData typeLenze SelectionC1510 FIX321 (P
Codes8 l 42EDS82ZAFVCxxx EN 4.0 FIF-STAT2FIF-OUT.W3FIF-OUT.W4FIF-STAT1Byte 4Byte 2Byte 3Byte 25, 26Byte 27, 28Byte 29, 30Byte 31, 32Byte1FIF-STA
Codes 8 l 43EDS82ZAFVCxxx EN 4.0 FIF status word 1 (FIF−STAT1) FIF status word 2 (FIF−STAT2)Bit Assignment Bit Assignment0 Current parameter s
Codes8 l 44EDS82ZAFVCxxx EN 4.0 C1511:Configuration of process output dataCode SubcodePossible settingsData typeLenze SelectionC1511 FIX321 (PAW
Codes 8 l 45EDS82ZAFVCxxx EN 4.0FIF-CTRL1FIF-CTRL2Byte 2Byte 1Byte 3Byte 4FIF-CTRL.B0FIF-CTRL.B1FIF-CTRL.B2FIF-CTRL.B4FIF-CTRL.B5FIF-CTRL.B6FI
Codes8 l 46EDS82ZAFVCxxx EN 4.0 FIF control word 1 (FIF−CTRL1) FIF control word 2 (FIF−CTRL2)Bit Assignment Bit Assignment0 / 1 JOG values (NSET
Codes 8 l 47EDS82ZAFVCxxx EN 4.0 C1512:I/O data enableCode SubcodePossible settingsData typeLenze SelectionC1512 ** − 655350[1] 65535 FIX32If
Codes8 l 48EDS82ZAFVCxxx EN 4.0C1518:I/O data lengthCode SubcodePossible settingsData typeLenze SelectionC1518 −41 [1] 12 FIX32This code determi
Codes 8 l 49EDS82ZAFVCxxx EN 4.0C1522:Display of all process data words to the basic deviceCode SubcodePossible settingsData typeLenze Selecti
About this documentationDocument history1 l 5EDS82ZAFVCxxx EN 4.0Target groupThis documentation is intended for all persons who plan, install,
Codes8 l 50EDS82ZAFVCxxx EN 4.0 C1523:Display of all process data words from the basic deviceCode SubcodePossible settingsData typeLenze Selecti
Codes 8 l 51EDS82ZAFVCxxx EN 4.0 C1525:Display of current DIP switch settingCode SubcodePossible settingsData typeLenze SelectionC15251g0 [1]
Codes8 l 52EDS82ZAFVCxxx EN 4.0 C1566:Automatic trip reset communication errorCode SubcodePossible settingsData typeLenze SelectionC1566 − 0 0
AppendixData transfer9 l 53EDS82ZAFVCxxx EN 4.09 Appendix9.1 Data transfer) Note!When using the DeviceNet communication profile, the correspon
AppendixData transfer9 l 54EDS82ZAFVCxxx EN 4.0 Two different telegram types are transferred between master computer and controller(s):ƒ I/O dat
AppendixData transferOverview of the implemented objects for the function module9 l 55EDS82ZAFVCxxx EN 4.0 9.1.1 Overview of the implemented o
AppendixData transferOverview of the implemented objects for the function module9 l 56EDS82ZAFVCxxx EN 4.0 DeviceNet Class (03hex)Instance 0:Att
AppendixData transferOverview of the implemented objects for the function module9 l 57EDS82ZAFVCxxx EN 4.0Assembly class (04hex)Instance 101 .
AppendixData transferOverview of the implemented objects for the function module9 l 58EDS82ZAFVCxxx EN 4.0Instance 114 ... 125:Attribute Service
AppendixData transferOverview of the implemented objects for the function module9 l 59EDS82ZAFVCxxx EN 4.0Connection Class (05hex)Instance 1 (
About this documentationConventions used1 l 6EDS82ZAFVCxxx EN 4.01.2 Conventions usedThis documentation uses the following conventions to distin
AppendixData transferOverview of the implemented objects for the function module9 l 60EDS82ZAFVCxxx EN 4.0Instance 2 (polled I/O data):Attribute
AppendixData transferOverview of the implemented objects for the function module9 l 61EDS82ZAFVCxxx EN 4.0Instance 4 (COS I/O):Attribute Servi
AppendixData transferOverview of the implemented objects for the function module9 l 62EDS82ZAFVCxxx EN 4.0 Acknowledge Handler Class (2Bhex)Inst
AppendixData transferOverview of the implemented objects for the function module9 l 63EDS82ZAFVCxxx EN 4.0 Manufacturer−specific class 100 (64
AppendixData transferOverview of the implemented objects for the function module9 l 64EDS82ZAFVCxxx EN 4.0 Manufacturer−specific class 102 (66he
AppendixData transferOverview of the implemented objects for the function module9 l 65EDS82ZAFVCxxx EN 4.0 Manufacturer−specific class 104 (68
Index10 l66EDS82ZAFVCxxx EN 4.010 Index8200 motec, Use with E82ZAFVC001, 10 8200 vector− Use with E82ZAFVC001, 10 − Use with E82ZAFVC010, 10
Index 10 l67EDS82ZAFVCxxx EN 4.0FFault elimination, 36 Functional insulation, 16 IIdentification, 11 Identity class, 55 Implemented object
Index10 l68EDS82ZAFVCxxx EN 4.0Screw−tightening torques, 27 Setting of the address, 32 Setting of the device address, 32 Settings, Front swit
Index 10 l69EDS82ZAFVCxxx EN 4.0
About this documentationNotes used1 l 7EDS82ZAFVCxxx EN 4.01.4 Notes usedThe following pictographs and signal words are used in this documenta
Q© 03/2012FLenze Drives GmbHPostfach 10 13 52D−31763 HamelnGermanyService Lenze Service GmbHBreslauer Straße 3D−32699 ExtertalGermany(+49(0)5154/ 8
Safety instructionsGeneral safety information2 l 8EDS82ZAFVCxxx EN 4.02 Safety instructions) Note!It is absolutely vital that the stated safety
Safety instructionsDevice− and application−specific safety instructions2 l 9EDS82ZAFVCxxx EN 4.02.2 Device− and application−specific safety in