Cam Designer Professional
L
78 Cam Designer Professional DE/EN 2.0
7.7.3 Close Cam Designer
When closing Cam Designer, a dialog box appears which indicates the status of the export data.
CAM Status of the profile
Table Status of the table of points
Export Status of the GDC export
Click Close to close Cam Designer Professional.
7.8 Export of cam profile data
Target system - 9300 EK servo cam profiler with GDC
1. Select File➞
➞➞
➞GDC Export... in Cam Designer Professional to open the GDC Export... dialog box.
2. Select the Comma radio button in the Decimal Point group box.
3. Select the Position radio button in the Type of Data group box.
4. Check Save to File.
5. Select OK to save the value pairs in a file. This opens the Save as dialog in which you can
specify the file name and the directory for the file.
Target system - Servo PLC/ECS
The data must be compiled before they are exported.
• Go to the interpolation modus.
• Choose the corresponding slave axis in the Cam Designer Professional via double click and then
press the button LCx in the menu.
If this function is executed fo r the first time, a dialog appears which is confirmed with OK. The system
willnowcreateafilewiththenameoftheslaveaxisandtheending*.lc9.
Compiling must be repeated for new cam profiles, cam controllers and any changes made.
After compiling, the data will be transferred to the *.lc9-file.
Double click Resources
➞
➞➞
➞CamSupport in the Drive PLC Developer Studio (DDS). Click Add Cam Data
to Project. A dialog appears in which you can select the *.lc9-file.
Tip!
Do not forget to save your Cam Designer Professional project on hard disk or diskette, in case you want
to make subsequent changes:
• Select File➞
➞➞
➞Save as... to save your Cam Designer Professional project under a new name.
Repeat the above-described steps to create further cam profiles by means of Cam Designer.
After creating all cam profiles required and exporting them for GDC, you can end Cam Designer
Professional with File
➞
➞➞
➞Exit.