H1inbet−ueb−rate einstellen
Setting the number of parameter data words (PCP)
ƒ You can use switches 5 and 6 or the code C13892 / C14892 to set the number of
parameter data words.
ƒ 0, 1, 2 or 4 parameter data words can be used.
ƒ The current setting is shown in C13860/1 / C14860/1.
Note!
The total number of data words (PD + PCP) must be between 1 and 10.
Impermissible settings are signalled by the "BE" LED (flashes
51) red).
The communication module then works internally with the following values:
ƒ PD = 2 (words)
ƒ PCP = 1 (word)
DIP switch Number of PCP
Switch
Max. number of
PD
ID code
[hex]
5 6
12345678
ON
OFF
0 OFF OFF 10 0x03
1 OFF ON 9 0xE3
2 ON OFF 8 0xE0
4 ON ON 6 0xE1