Installation
Electrical installation
Operation in the standard Ethernet
5
28
EDSMF2191IB EN 2.0
5.2.4 Operation in the standard Ethernet
Note!
Operation in the standard Ethernet does not permit any real−time
communication.
The communication module can be operated in the standard Ethernet for a basic
parameter setting provided that the following applies:
1. Operation of the module in slave mode:
– Network address 239
– IP address: 192.168.100.<EPL address>
2. Real time operation must not be carried out.
3. No integration of a master (EPL address 240) into the standard Ethernet network.
More notes on wiring
ƒ Do not wire, if possible, more than 9nodes in succession in a network line.