25 RG-MHMOD
Drive Control & Communication
NOTE 4 - Acceleration Limits
Acceleration Limits
HP Adjustment Range
0.25 - 20 1 - 36000 (0.1 - 3600 sec)
25 - 60 3 - 36000 (0.3 - 3600 sec)
75 - 250 6 - 36000 (0.6 - 3600 sec)
NOTE 5 - Deceleration Limits
Deceleration Limits
HP Adjustment Range
240/200 VAC 480/400 VAC 590/480 VAC without dB with dB
0.25 - 7.5 1 - 7.5 3 - 36000 (0.3 - 3600 sec) 1 - 36000 (0.1 - 3600 sec)
10 - 15 10 - 20 1 - 7.5 5 - 36000 (0.5 - 3600 sec) 1 - 36000 (0.1 - 3600 sec)
20 - 30 25 - 60 10 - 20 10 - 36000 (1.0 - 3600 sec) 2 - 36000 (0.2 - 3600 sec)
25 - 60 20 - 36000 (2.0 - 3600 sec) 2 - 36000 (0.2 - 3600 sec)
NOTE 6 - MAX DC BRAKE VOLTAGE (Register 63)
Maximum DC Brake Voltage
Model MH100 MH200 MH400 MH500
Voltage 240/120 Vac 240/200 Vac 480/400 Vac 590/480 Vac
MAX Brake Voltage 24 V 24 V 48 V 59 V
NOTE 7 - CURRENT (Register 67)
If LINE VOLTS, Register 51, is set to LOW (or set to Auto and the input voltage is low), the range for
CURRENT is 25 - 150%.
NOTE 8 - FX BOOST (Register 70)
FX BOOST Factory Default Setting
HP Factory Default HP Factory Default
0.25 - 1 5.30% 15 2.20%
1.5 - 2 4.40% 20 2.00%
3 3.60% 25 1.80%
5 3.00% 30 1.60%
7.5 2.70% 40 1.20%
10 2.40% 50 - 60 0.80%
Kommentare zu diesen Handbüchern