Lenze E84DGFCG Bedienungsanleitung Seite 32

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 149
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 31
Lenze · Decentralised frequency inverter 8400 motec (EtherNet/IP™ option) · EDS84DMOTEIP EN 2.0 - 10/2013 32
Commissioning
Setting the IP configuration of the Inverter Drive 8400 motec
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
2. A double-click on a EtherNet/IP node opens the "Configure nodes" dialog window.
Here you can set the IP parameters.
3. Click on Transferred.
The IP configuration is transferred to the corresponding EtherNet/IP node.
The Communication Unit executes a stack reset.
•The IP parameters are written to codes C13000
(IP address), C13001 (subnet mask), and
C13002
(gateway address).
•Code C13005
(IP configuration reference) is set to ’0: Saved address’ to ensure that the
transferred address can be used.
Tip!
Check whether the configuration has been transferred successfully.
For this purpose, open the "Assign IP addresses" dialog window (see step 1) and click the
Find device button.
Seitenansicht 31
1 2 ... 27 28 29 30 31 32 33 34 35 36 37 ... 148 149

Kommentare zu diesen Handbüchern

Keine Kommentare