12 Error messages
12.2 Possible causes and remedies
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
12.2 Possible causes and remedies
This chapter lists all EtherCAT error messages in the numerical order of the error numbers. Possible
causes and remedies as well as responses to the error messages are described in detail.
Lost connection to 8400 [0x01bc3100]
Memory: No access [0x01bc5531]
Memory: Read error [0x01bc5532]
Memory: Write error [0x01bc5533]
Restart by watchdog reset [0x01bc6010]
Response (Lenze setting printed in bold) Setting: not possible
None System fault Fault Trouble Quick stop by trouble Warning locked Warning : Information
Cause Remedy
MCI communication for the Inverter Drives 8400 is
interrupted.
• Inverter Drive 8400 is switched off.
• The communication module has not been inserted
properly into the slot of the Inverter Drives 8400.
• Switch on Inverter Drive 8400.
• Check screwed connection of the communication
module to the MC slot of the Inverter Drive 8400.
Send communication module and Inverter Drive 8400
with error description to Lenze.
Response (Lenze setting printed in bold) Setting: not possible
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Access via standard device to parameter set within the
memory module was not successful.
Repeat download of the application (including module).
Response (Lenze setting printed in bold) Setting: not possible
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Parameters of the memory module could not be read. Repeat download of the application (including module).
Response (Lenze setting printed in bold) Setting: not possible
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Parameters of the memory module could not be written. Repeat download of the application (including module).
Response (Lenze setting printed in bold) Setting: not possible
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Communication module is defective. Send communication module with error description to
Lenze.