Seitenansicht 53
Communication manual 8400 protec PROFINET
PROFIsafe
54 L EDS84DPNET EN 4.0 - 11/2010
9PROFIsafe
PROFINET enables the transmission of safe information via the PROFIsafe protocol
according to the "PROFIsafe - Profile for Safety Technology" specification, version 2.0.
The PROFIsafe messages are sent in the second slot of a PROFINET telegram.
In the PROFIsafe messages, every bit serves to control a specific safety function.
The structure of the PROFIsafe messages is described in the PROFIsafe profile.
The length of the PROFIsafe messages is always 8 bytes.
Note!
Safe information can only be transmitted via the PROFIsafe protocol when using
a version with integrated safety system.
Safety engineering manual "Inverter Drives 8400 protec"
Here you can find detailed information on devices with an integrated safety
system.
Software manual/»Engineer« online help for the Inverter Drive 8400 protec
Here you can find detailed information about the PROFIsafe connection.