EDS84DPNET EN 4.0 - 11/2010 L 69
Communication manual 8400 protec PROFINET
Parameter reference
Parameters relevant for communication
C13010
C13011
C13012
Parameter | Name:
C13010 | Active IP address
Data type: UNSIGNED_8
Index: 11565
d
= 2D2D
h
Display of the active IP address
• The active IP address may differ from the contents of code C13000
, depending on whether the station name was
changed via the fieldbus or the parameter.
Display range (min. value | unit | max. value)
0 255
Subcodes Information
C13010/1 Active IP address.1
C13010/2 Active IP address.2
C13010/3 Active IP address.3
C13010/4 Active IP address.4
; Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13011 | Active subnetwork mask
Data type: UNSIGNED_8
Index: 11564
d
= 2D2C
h
Display of the active subnetwork mask
• The active subnetwork mask may differ from the contents of code C13001
, depending on whether the station
name was changed via the fieldbus or the parameter.
Display range (min. value | unit | max. value)
0 255
Subcodes Information
C13011/1 Active subnetwork mask.1
C13011/2 Active subnetwork mask.2
C13011/3 Active subnetwork mask.3
C13011/4 Active subnetwork mask.4
; Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13012 | Active gateway address
Data type: UNSIGNED_8
Index: 11563
d
= 2D2B
h
Display of the active gateway address
• The active gateway address may differ from the contents of code C13002
, depending on whether the station
name was changed via the fieldbus or the parameter.
Display range (min. value | unit | max. value)
0 255
Subcodes Information
C13012/1 Active gateway address.1
C13012/2 Active gateway address.2
C13012/3 Active gateway address.3
C13012/4 Active gateway address.4
; Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT