Lenze · E94AYCIB communication module (INTERBUS) · Communication Manual · DMS 4.0 EN · 02/2014 · TD17 39
9 Parameter data transfer
9.1 Addressing of the parameter data
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
9 Parameter data transfer
The parameter data of Lenze devices are contained in codes which are listed in this documentation
and the documentation of the Servo Drive 9400.
Parameter reference
( 53)
9.1 Addressing of the parameter data
The parameters of a Lenze device are not directly addressed via codes but via an index and subindex.
The conversion is made via an offset: 24575 or 0x5FFF
• INTERBUS index (decimal) = 24575 - Lenze code number (decimal)
• INTERBUS index (hexadecimal) = 0x5FFF - Lenze code number (hexadecimal)
Example of C00105 (deceleration time quick stop (QSP)):
• INTERBUS index (decimal) = 24575 - 105 = 24470
• INTERBUS index (hexadecimal) = 0x5FFF - 0x69 = 0x5F96
Parameter changes must be saved via code C00002 of the Servo Drive 9400.
Kommentare zu diesen Handbüchern