Control technology | EtherCAT communication manual
Diagnostics
System error messages
158 L DMS 3.1 EN 01/2011 TD17
SLV Distributed Clocks latching status [...] ([...]) Distributed clocks - latching status
SLV CoE: SDO Download failure, statVal=[...], errCode=[...] ([...]) CoE: SDO download has failed.
SLV CoE: SDO Upload failure, statVal=[...], errCode=[...] ([...]) CoE: SDO upload has failed.
SLV CoE: OD-List Upload failure, statVal=[...], errCode=[...] ([...]) CoE: OD list upload has failed.
SLV CoE: Object Description Upload failure, statVal=[...], errCode=[...]
([...])
CoE: Object description upload has failed.
SLV CoE: Object Entry Description Upload failure, statVal=[...],
errCode=[...] ([...])
CoE: Object entry description upload has failed.
SLV CoE: Emergency transfer failure, statVal=[...], errCode=[...]([...]) CoE: Emergency transfer has failed
SLV CoE: Emergency request, id=[...], len=[...] ===> slave address=[...],
ErrCode=[...], ErrReg=[...], data: '[...] [...] [...] [...] [...]'.
CoE: Emergency request to slave [...]
SLV Cyclic command working counter error - Command: [...] -
Logical/Physical address: [...], WKC act/set=[...]/[...]
Cyclic command - WKC error at the node with the logic/physical
address [...]
SLV Master init command working counter error - Command: [...] -
Logical/Physical address: [...], WKC act/set=[...]/[...]
Master init command - WKC error at the node with the logic/
physical address [...]
SLV Slave init command working counter error - Properties for slave
\"[...]\": - EtherCAT address=[...] - Command: [...] - Logical/
Physical address: [...], WKC act/set=[...]/[...]
Slave init command - WKC error at the node with the logic/
physical address [...]
SLV EoE receive working counter error - Properties for slave \"[...]\": -
EtherCAT address=[...] - Command: [...] - Logical/Physical
address: [...], WKC act/set=[...]/%6!lu!
EoE receive - WKC error at the slave with the logic/physical
address [...]
SLV CoE receive working counter error - Properties for slave \"%1!hs!
- EtherCAT address=%2!lu! - Command: %3!hs! - Logical/
Physical address: 0x%4!lx!, WKC act/set=[...]/[...]
CoE receive - WKC error at the slave with the logic/physical
address [...]
SLV FoE receive working counter error - Properties for slave \"[...]\": -
EtherCAT address=[...] - Command: [...] - Logical/Physical
address: [...], WKC act/set=[...]/[...]
FoE receive - WKC error at the slave with the logic/physical
address [...]
SLV SoE receive working counter error - Properties for slave \"[...]\": -
EtherCAT address=[...] - Command: [...] - Logical/Physical
address: [...], WKC act/set=[...]/[...]
SoE receive - WKC error at the slave with the logic/physical
address [...]
SLV EoE send working counter error - Properties for slave \"[...]\": -
EtherCAT address=[...] - Command: [...] - Logical/Physical
address: [...], WKC act/set=[...]/[...]
EoE send - WKC error at the slave with the logical/physical
address [...]
SLV CoE send working counter error - Properties for slave \"[...]\": -
EtherCAT address=[...] - Command: [...] - Logical/Physical
address:[...], WKC act/set=[...]/[...]
CoE send - WKC error at the slave with the logical/physical
address [...]
SLV FoE send working counter error - Properties for slave \"[...]\": -
EtherCAT address=[...] - Command: [...] - Logical/Physical
address: [...], WKC act/set=[...]/[...]
FoE send - WKC error at the slave with the logical/physical
address [...]
SLV SoE send working counter error – Properties for slave \"[...]\": -
EtherCAT address=[...] – Command: [...] – Logical/Physical
address: [...], WKC act/set=[...]/[...]
SoE send - WKC error at the slave with the logical/physical
address [...]
SLV Additional error information: [...] Additional error information [...]
SLV Ecat command IDX act value=[...] EtherCAT command - IDX actual value
SLV Ecat command IDX set value=[...] EtherCAT command - IDX setpoint
SLV Init command response error – Properties for slave \"[...]\": -
EtherCAT address=[...] – Current State change of slave=\"[...]\"
No Response, is there a slave at this position?]
Response error to Init command to slave [...]:
No response: Is there a slave at this position?
SLV Init command response error – Properties for slave \"[...]\": -
EtherCAT address=[...] – Current State change of slave=\"[...]\"
Validation error, is the correct slave at this position?
Response error to Init command to slave [...]:
Validation error: Is the correct slave at this position?
SLV Init command response error – Properties for slave \"[...]\": -
EtherCAT address=[...] – Current State change of slave=\"[...]\"
target state could not be reached, is the correct slave at this
position?
Response error to Init command to slave [...]:
Target state has not been reached. Is the correct slave at this
position?
SLV Master init command response error – Current State change of
master=\"[...]\" No Response, is there anything connected?
Response error to master init command:
State change of the master
No response: Is there anything connected at all?
SLV Master init command response error – Current State change of
master=\"[...]\" Validation error, are the correct slaves
connected?
Response error to master init command:
State change of the master
Validation error, are the correct slaves connected?
SLV Missing EtherCAT [...] command in Ethernet frame – Properties
for slave \"[...]": - EtherCAT address=[...] – Index of missing
command in the Ethernet frame=[...]
EtherCAT command [...] is missing in the Ethernet frame to slave
[...].
SLV Mailbox Slave init command timeout – Properties for slave
\"[...]\": - EtherCAT address=[...] – Current State change of
mailbox slave=\"[...]\
Time-out "Mailbox init command" to slave [...]
Error type Error text in the IPC logbook Description
Kommentare zu diesen Handbüchern