Seitenansicht 162
DMS 5.2 EN 03/2011 TD17 L 163
L-force | PLC Designer - SoftMotion
The SM_PLCopen.lib library
Additional program organisation units
6.4.5 SMC_GetTappetValue
This program organisation unit evaluates the Tappets output of the MC_CamIn program
organisation unit and contains the current tappet status.
Inputs/outputs (VAR_IN_OUT)
Tappets : SMC_TappetData
Inputs (VAR_IN)
iID : INT
Group ID of the tappet to be evaluated
bInitValue : BOOL
Initial tappet value, assigned on the first call
bSetInitValueAtReset : BOOL
TRUE: When the CamIn FB is restarted, the value of the tappet is set to bInitValue.
FALSE: When the CamIn FB is restarted, the tappet value is retained.
Outputs (VAR_OUT)
bTappet : BOOL (default: FALSE)
Tappet value