9300 Servo PLC
Appendix
3.6 Code table
3−49
L
9300 Servo PLC EN 5.0
Code InfoPossible settingsLCDCode Info
SelectionLenze
LCD
C2120 AIF: Control 0 AIF−CAN: Control word
0 [1] 255
Decimal value is bit−coded:
Note: The state of the MSB (bit 7) of the control word
automatically changes with each access to the code. Please
take this into account when interpreting the data!
0 No command
1 Read XCAN code + new initialization
2 Read XCAN codes
10 Read XCAN C2356/1 ... 4
11 Read XCAN C2357
12 Read XCAN C2375
13 Read XCAN C2376 ... C2378
14 Read XCAN C2382
255 Not assigned
C2121 AIF: state
g
AIF−CAN: Status
Detailed information can be found in the documentation
for the corresponding fieldbus module.
0 {dec} 255
Decimal value is bit−coded:
Bit 0 XCAN1_IN monitoring time
Bit 1 XCAN2_IN monitoring time
Bit 2 XCAN3_IN monitoring time
Bit 3 XCAN bus off
Bit 4 XCAN operational
Bit 5 XCAN pre−operational
Bit 6 XCAN warning
Bit 7 Internally assigned
C2130 FileNameAddDa
g
Symbolic name of data
Information about the additional data that was transferred
to the PLC together with the PLC program.
More detailed information can be found in chapter
3.3.3, "Downloading data". ^ 3−6
C2131 Type AddData
g
Data specification identifier
C2132 VersionAddData
g
Data version
C2133 TimeStamp
g
Time stamp of data
C2350 XCAN Address 1 AIF−CAN: Node address
1 {1} 63
C2351 XCAN baudrate 0 AIF−CAN: Baud rate
0 500 kbit/s
1 250 kbps
2 125 kbps
3 50 kbps
4 1000 kbps
5 20 kbps
6 10 kbps
C2352 CAN mst 0 AIF−CAN: Set−up "quasi" master
Controller sends system bus boot−up and is thus the
"quasi" master.
0 Boot−up not active
1 Boot−up active
C2353 CAN addr sel1 AIF−CAN: Source for PDO identifiers
0 Identifier assignment via C2350 + basic identifier
1 Identifier assignment via C2354/x
1 0 XCAN1_IN/OUT
2 0 XCAN2_IN/OUT
3 0 XCAN3_IN/OUT