Technical d ata
3-1
L BA2141 EN 1.0
3 Technical data
3.1 Features of the 2141 fieldbus module
Attachable additional module for the following devices:
– 82XX
– 8200 vector
– Drive PLC
– 93XX
– 9300 Servo PLC
LON connection module with the LONMARK
®
Functional Profile “Variable Speed Motor
Drive”
Access to all Lenze parameters
Internal and external 24-V-DC voltage supply possible with devices listed above
(exception 820X: only external supply)
3.2 General data / application conditions
Field Values
Order name EMF2141IB
Network topology Free topology (line, tree, star, ring)
Possible number of nodes 64
Max. cable length 2700 m with bus t o pology
500 m if the topology is mixed
Baud rate 78 kBit/s
Ambient temperature during
operation:
during
transport:
during storage:
C ... 55° C
-25° C ... 70° C
-25° C ... 60 °C
Permissible humidity Class 3K3 to EN 50178 (without condensat io n, average rela t ive humidity 85%)