8.5 System error messages
Drive PLC
Appendix
8−12
L
DrivePLC DE 6.0
8.5.4 Cause & remedy
No. Display Meaning Cause Remedy
−−− −−− No error − −
061 CE0 Communication error
AIF moduleóBasic unit
Interference during transfer of control commands
via automation interface (AIF)
Plug in automation module firmly, bolt down, if
necessary
062 CE1 CAN1_IN communication error
CANx_IN receives faulty data or communication
interrupted
Check wiring/cable
Check transmitter
If possible, increase monitoring time under
C0357/x
063 CE2 CAN2_IN communication error
064 CE3 CAN3_IN communication error
065 CE4 CAN BUS−OFF status
(too many faulty telegrams
received)
PLC has received too many faulty telegrams sent
via system bus and has disconnected itself from
the bus
Check wiring/cable
Check bus termination (if any)
Check screen contact of the cables
Check PE connection
Check bus load
Reduce baud rate (observe cable length)
066 CE5 CAN time−out
(gateway function)
For remote parameterisation via system bus
(C0370):
Slave does not respond
Communication monitoring time exceeded
Check system bus wiring/cable
Check system bus configuration
070 U15 Undervoltage of internal 15 V
voltage supply
Check voltage supply for Drive PLC
071 CCR Internal error The program sequence of the processor was
interfered
Shield control and motor cables as necessary
Check PE wiring and PE connections
072 PR1 Check sum error
in parameter set 1
CAUTION:
Lenze setting is loaded
automatically!
Error while loading a parameter set
Interruption of parameter set transfer via
keypad (e.g. by disconnection of the keypad)
Set the desired parameters and save them
under C0003
For PR0 the supply voltage must be switched
off additionally
Check use of pointers
The saved parameters do not match the loaded
software version
Before an error can be acknowledged, the
parameter set must be manually saved under
C0003
074 PEr Program error Error detected in program Check use of pointers
Send controller with parameter set and PLC
program (on diskette) to Lenze
075 PR0 General error in parameter sets
CAUTION:
Lenze setting is loaded
automatically!
See Cause & Remedy, no. 072 (PR1)
076 PR5 Error while saving parameters Error while saving parameters in the fail−safe
memory area
Contact Lenze
079 PI Error during
parameter initialisation
Error detected during parameter set transfer
between two controllers
Parameter set does not match the PLC or
controller (e.g. data transfer from a
high−performance controller to a
lower−performance controller)
Correct the parameter set
Check code initialisation values
080 PR6 Too many user codes Reduce the number of user codes
x09 EEr External monitoring activated
via DCTRL
A digital signal assigned to the TRIP−SET function
has been activated (system block DCTRL is
integrated as of software version V8.0)
Check external encoder
Deactivate monitoring (C0581 = 3)
105 H05 Internal error (memory) Contact Lenze
108 H08 Extension board error
Extension board not connected correctly Connect extension board properly
Check connection plug EBóPLC
Extension board is not supported by PLC program Adapt PLC program to extension board
Use extension board which is supported by PLC
program.
122 CE11 Communication error
FIF−CAN1_IN
FIF−CANx_IN receives faulty data or
communication interrupted
Check wiring/cable
Check transmitter
If possible, increase monitoring time under
C2457/x
123 CE12 Communication error
FIF−CAN2_IN
124 CE13 Communication error
FIF−CAN3_IN