2.5 EN - 01/2012 L 95
Industrial PC | Parameter setting & configuration
Remote maintenance and diagnostics
Windows® CE functions
12.4.1 Remote Display
The Engineering PC requires the Remote Display Control software (cerhost.exe) which can
be downloaded from the AKB on the Lenze homepage. It is also provided on the CD that is
delivered along with the devices.
How to establish a Remote Display connection to the Industrial PC:
1. Find out the IP address of the Engineering PC (e.g. by executing the IPConfig command),
2. Start Remote Display Control (cerhost.exe) on the Engineering PC,
3. Start cerdisp.exe on the IPC: cerdisp <IP address>.