8 Diagnostics
LED status displays
EDK82ZAFPC-010 DE/EN/FR 6.0
70
H1_Diagnose----(DUMMYSEITEVOR)---
8 Diagnostics
LED status displays
2
1
E82ZAFPC010
E82ZAFP016
LED
Description
Pos. Colour Condition
yellow
off No communication with the PROFIBUS master.
blinking Communication with the PROFIBUS master has been established
via the function module.
green
off
The function module is not supplied with voltage.
The standard device and/or the external voltage supply is
switched off.
blinking The function module is supplied with voltage but is not connected
to the standard device.
Causes:
The standard device is switched off.
The standard device is in the initialisation phase.
The standard device is not available
on The function module is supplied with voltage and is connected to
the standard device.

+
yellow/
green
blinking Internal function module error