Communication manual 8400 motec PROFINET
Error messages
Possible causes and remedies
70 L EDS84DMOTPNET EN 2.0 - 11/2011
PROFINET: Internal error [0x01bc6011]
PROFINET: Internal error [0x01bc6100]
PROFINET: Internal error [0x01bc6101]
PROFINET: Invalid parameter set [0x01bc641f]
PROFINET: Error: Lenze setting loaded [0x01bc6420]
PROFINET: Invalid module configuration [0x01bc6430]
Response (Lenze setting printed in bold) Setting: C01501/2 (; Adjustable response)
; None System fault : Fault Trouble Quick stop by trouble ; Warning locked Warning Information
Cause Remedy
Device is damaged. Send device with error description to Lenze.
Response (Lenze setting printed in bold) Setting: C01501/2 (; Adjustable response)
; None System fault : Fault Trouble Quick stop by trouble ; Warning locked Warning Information
Cause Remedy
Device is damaged. Send device with error description to Lenze.
Response (Lenze setting printed in bold) Setting: C01501/2 (; Adjustable response)
; None System fault : Fault Trouble Quick stop by trouble ; Warning locked Warning Information
Cause Remedy
Device is damaged. Send device with error description to Lenze.
Response (Lenze setting printed in bold) Setting: C01501/2 (; Adjustable response)
; None System fault : Fault Trouble Quick stop by trouble ; Warning locked Warning Information
Cause Remedy
No active parameter set could be loaded Download application again (including module).
Send device with error description to Lenze.
Response (Lenze setting printed in bold) Setting: not possible
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Access to parameter set was not possible. Download application again (including module).
Send device with error description to Lenze.
Response (Lenze setting printed in bold) Setting: C01501/2 (; Adjustable response)
; None System fault : Fault Trouble Quick stop by trouble ; Warning locked Warning Information
Cause Remedy
A module or submodule does not comply with the
configuration of the Siemens S7 engineering tool.
Check and correct module configuration.