Lenze E84DGFCR Bedienungsanleitung Seite 79

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 90
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 78
EDS84DMOTPNET EN 2.0 - 11/2011 L 79
Communication manual 8400 motec PROFINET
Parameter reference
Parameters relevant for PROFINET communication
C13864
C13867
Parameter | Name:
C13864 | Active station name
Data type: VISIBLE_STRING
Index: 10711
d
= 29D7
h
Displays the active station name used by the controller.
It may differ from the contents of code C13899
, depending on whether the station name has been changed via the
fieldbus or via C13899
.
Setting the station name
( 28)
Subcodes Info
C13864/1 1st ... 30th character
C13864/2 31th ... 60th character
C13864/3 61th ... 90th character
C13864/4 91th ... 120th character
C13864/5 121th ... 150th character
C13864/6 151th ... 180th character
C13864/7 181th ... 210th character
C13864/8 211th ... 240th character
; Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13867 | Display: Most recent diagnostic data
Data type: OCTET_STRING
Index: 10708
d
= 29D4
h
Display of diagnostic data sent by the controller most recently:
; Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Bytes Information
0Slot
1
2Subslot
3
4 Error code
...
7
8Slot
9
10 Subslot
11
12 Error code
...
15
Seitenansicht 78