Communication manual 8400 motec PROFINET
Parameter reference
Parameters relevant for PROFINET communication
74 L EDS84DMOTPNET EN 2.0 - 11/2011
13.2 Parameters relevant for PROFINET communication
This chapter lists the PROFINET parameters of the Communication Unit in numerically
ascending order.
C13000
C13001
Note!
PROFINET command "Reset to factory defaults"
If the "Reset to factory defaults" PROFINET command is executed by an IO
supervisor or an I/O controller, the PROFINET-specific parameters will be reset to
their standard values:
C13000
| IP address
C13001
| Subnetwork mask
C13002
| Gateway address
C13010
| Active IP address
C13011
| Active subnetwork mask
C13012
| Active gateway address
C13864
| Active station name
C13887
| Suppress signalling diag. mess. upon
C13899
| Station name
C13910
| I&M1 system designation
C13911
| I&M1 installation site
C13912
| I&M2 installation date
C13913
| I&M3 additional information
C13914
| I&M4 signature code
Parameter | Name:
C13000 | IP address
Data type: UNSIGNED_32
Index: 11575
d
= 2D37
h
Setting of the IP address
Setting the IP configuration
( 30)
Setting range (min. value | unit | max. value) Lenze setting
0 4294967295 0
; Read access ; Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13001 | Subnetwork mask
Data type: UNSIGNED_32
Index: 11574
d
= 2D36
h
Setting of the subnet mask
Setting the IP configuration
( 30)
Setting range (min. value | unit | max. value) Lenze setting
0 4294967295 0
; Read access ; Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT