Lenze ECSCExxx Bedienungsanleitung Seite 94

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 164
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 93
Electrical installation
Power terminals
Connection of an ECSxK... capacitor module (optional)
4
94
EDKCSCE040 DE/EN/FR 3.0
L3
N
L1
L2
F4
K1
ECSxK...
K1
K1
L1 L2
L3
ECSxE...
PE
X21
+UG
+UG
+UG
+UG
+UG
-UG
-UG
-UG
-UG
-UG
PE
PE
PE
PE
PE
X22
X23
Off
On
+UG
BR1
X26
BR0
X23
T1
T2
X6
DI1
DI2
DO1
D24
+24V
GND
GND
24VDC
+
-
2
1
0
M
3~
R
J
2
6
UV
W
PE
X24
BD1
BD2
X25
X7
+
"
"
"
"
F1...F3
Z1
"
"
"
"
ECSxS/P/M/A...
ECSXX004
Fig. 4−6 Wiring of capacitor module ECSxK...
HF−shield termination by large−surface connection to functional earth (see
Mounting Instructions for ECSZS000X0B shield mounting kit)
Twisted cables
K1 Mains contactor
F1 ... F4 Fuse
Z1 Mains choke / mains filter, optional
Contactor relay
System cable ˘ feedback
Terminal X6/SI1 of the connected axis modules (controller enable/inhibit)
Seitenansicht 93