Lenze · ApplicationTemplate PackML · 1.0 EN - 05/2014 79
Architecture: The ApplicationTemplate PackML in detail
Central management of alarms
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
In order to couple the Modul_1 slave module to the master again, first the reason for the alarm has
to be removed.
• By means of a procedure, both state machines of master and slave module have to be
synchronised.
• The deactivated slave module has to be coupled again to the state machine of the master
module using the Command_DisableModule method. Renewed coupling of machine
modules ( 72)
9.10 Central management of alarms
The alarm handling transmits all alarms that occur in the machine modules to the global Alarm List.
• The state machine of the Modul_1 slave
module is decoupled automatically from the
master module. "Module Disabled" is
highlighted in red.
• The state machine changes to the
"ABORTING" state.
•The Machine Control master module remains
unchanged in the "EXECUTE" state.
• The machine modules forward the
messages to the Alarm List Handler.
• All current alarms are visible in the
global Alarm List.