An overview of the methods
An overview of the command methods: Command_xxx
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Command_CtrlCmd
Changeover of the prevailing transitions of
the PackML state machine.
Inputs
eCtrlCmd
L_EATP_CtrlCmds_PackML
Desired status to be set of the
machine module requested.
xCmdChangeRequest
BOOL
TRUE: Request desired status.
Command_DisableModule
Activates/deactivates the decoupling of a
slave machine module from the master.
Inputs
MM_Address
L_EATP_MM_Address
ID of the module the status of which
is to be requested. The value "0" and
L_EATP_CONST.OWNID address the
module's own ID.
xValue
BOOL
TRUE: Activate decoupling.
FALSE: Deactivate decoupling:
The machine module is coupled to
the master module.
Command_SendAlarmReactionIfDisabled
Activates/deactivates the transfer of alarm
reaction types to the master module even if
the module is deactivated (DisableModule).
Inputs
MM_Address
L_EATP_MM_Address
ID of the module the status of which
is to be requested. The value "0" and
L_EATP_CONST.OWNID address the
module's own ID.
xSend... Activates/deactivates the transfer of
an alarm reaction type:
TRUE: Activate the transfer of the
type/
FALSE: Deactivate the transfer of the
type.
•...SystemFault
•...Abort
•...Stop
•...Fault
BOOL
Reaction type "System fault"
Reaction type "Abort"
Reaction type "Stop"
Reaction type "Fault"
Command_UnitMode
Changeover of the modes from the states
that are defined in the PackMLConfig
program. Predefined operating modes in
ModApp1 ( 20)
Inputs
eUnitMode
L_EATP_Modes_PackML
Mode to be set.
xUnitModeRequest
BOOL
TRUE: Request desired mode.
Identifier/function Transfer value/data type Description