Seitenansicht 63
Mechanical installation
Important notes
5
64
EDS700ACBA EN 4.0
5 Mechanical installation
5.1 Important notes
Danger!
Sticker with warning note must be displayed prominently and close to the
device!
Note!
The devices must be installed in housings (e.g. control cabinets) to meet
applicable regulations.
Summary of important notes on mechanical installation
ƒ Mount the devices vertically ( 28)
– DC−bus voltage connections (X101/102): at the top
– Fan unit: at the bottom
ƒ Observe mounting clearances ( 28):
– If unimpeded ventilation of the modules is ensured, the connecting cables can be
installed in the mounting clearances
– The modules can be mounted side−by−side without any clearance
ƒ Requirements for the mounting and supporting surface to ensure an EMC−compliant
installation without the need for additional measures:
– Electrically conductive
– Free of lacquer and protected against corrosion or made of rust−proof metal
– Completely flat and smooth surface
ƒ In case of push−through installation (thermal separation), the heatsink protrudes
through the mounting cutout of the mounting wall.
– The design of the mounting wall must ensure the tightness towards the device
surface.
– Prevent the mounting wall from being bent or twisted.
ƒ In order to comply with the permissible pollution degree of the ambient air, ( 27)
provide additional measures:
– Separate or filtered air flow against dust, fluff, grease, aggressive gas
– Ensure regular cleaning
ƒ Observe permissible ambient temperatures − also in the control cabinet ( 27).