Function library LenzeDrive.lib
Signal conversion
2.5.1 Normalization (L_CONV)
2−49
L
LenzeDrive.lib EN 1.7
2.5 Signal conversion
2.5.1 Normalization (L_CONV)
This FB normalizes signals. The calculation is made quite precisely, with remainder processing and
definition of the conversion factor as a numerator and denominator.
n I n _ a
n O u t _ a
L _ C O N V
n N u m e r a t o r
n D e n o m i n a t o r
Fig. 2−59 Normalization (L_CONV)
VariableName DataType SignalType VariableType Note
nIn_a Integer analog VAR_INPUT 100 % 16384 C0011 (n
max
)
nOut_a Integer analog VAR_OUTPUT The signal it limited to ±199.99 % (100 % 16384).
nNumerator Integer VAR CONSTANT RETAIN Numerator
nDenominator Integer VAR CONSTANT RETAIN Denominator
Parameter codes of the instances
VariableName L_CONV1 L_CONV2 L_CONV3 SettingRange Lenze
nNumerator C0940 C0945 C0950 −32767 ... 32767 1
nDenominator C0941 C0946 C0951 1 ... 32767 1
VariableName L_CONV4 L_CONV5 L_CONV6 SettingRange Lenze
nNumerator C0955 C0655 C1170 −32767 ... 32767 1
nDenominator C0956 C0656 C1171 1 ... 32767 1
Function
The multiplication or division of signals is made according to the formula:
nOut + nIn @
nNumerator
nDenominator
Seitenansicht 58