Function library LenzeDrive.lib
Preface and general information
1.2 Lenze software guidelines for variable names
1−5
L
LenzeDrive.lib EN 1.7
1.2.1.2 Designation of the signal type in the variable name
The inputs and outputs of the Lenze function blocks each have a specific signal type assigned. These
may be: digital, analog, position, or speed signals.
For this reason, each variable name has an ending attached that provides information on the type of
signal.
Signal type Ending Previous designation
analog _a (analog)
H
digital _b (binary)
G
Phase−angle difference or speed _v (velocity)
F
Phase−angle or position _p (position)
E
Tip!
Normalizing to signal type phase−angle difference/speed: 16384 (INT) ¢ 15000 rpm
Normalizing to signal type analog: 16384 ¢ 100 % ¢ value under [C0011] = n
max
Normalizing to signal type angle or position: 65536 ¢ 1 motor revolution
Examples:
Variable name Signal type Type of variable
nIn_a Analog input value Integer
dnPhiSet_p Phase signals Double integer
bLoad_b Binary value (TRUE/FALSE) Bool
nDigitalFrequencyIn_v Speed input value Integer
1.2.1.3 Special handling of system variables
System variables require special handling, since the system functions are only available for the user
as I/O connections in the control configuration.
In order to be able to access a system variable quickly during programming, the variable name must
include a label for the system function.
For this reason, the name of the corresponding system block is placed before the name of the
variable.
Examples:
AIN1_nIn_a
CAN1_bCtrlTripSet_b
DIGIN_bIn3_b