E84AYCEC communication manual (Ethernet POWERLINK)
Technical data
Ethernet POWERLINK communication data
20 L EDS84AYCEC EN 3.0 - 09/2012
4.3 Ethernet POWERLINK communication data
Communication time
The communication time is the time between the start of a request and the arrival of the
corresponding response.
The communication times in the Ethernet POWERLINK network depend on ...
the processing time in the controller;
the telegram runtime (baud rate / telegram length);
the nesting depth of the network.
Processing time in the controller
There are no interdependencies between parameter data and process data.
Field Values
Min. cycle time 400 s
Total cycle times 0.4 / 0.5 / 1.0 / 2.0 / 3.0 … 20.0 ms
Buffer size Tx-iso: max. 1490 bytes
Rx-iso: max. 1490 bytes
(max. 32 bytes of PDO user data)
Delay time Controlled node (T
Preq
- T
Res
): approx. 2.6 s
Controlled node (T
SoA
- T
ASnd
): approx. 2.6 s
Frame size Max. asynchronous frame size (MTU): 1518 bytes
SDO communication method UDP/IP or ASND
Number of RPDOs Max. 6 channels
RPDO user data per application (all
RPDOs)
Max. 16 objects (max. 32 bytes)
Number of TPDOs 1 channel (data access of all nodes by broadcasting)
TPDO user data per application Max. 16 objects (32 bytes)
CN operating modes Support of ...
•Multiplex CNs
•Optional CNs
Data Processing time
Process data approx. 2 ms
+ 0 ... 1 ms
+ 1 ... x ms
Update cycle
Processing time in the module
Runtime of the application task of the technology
application used (tolerance)
Parameter data approx. 30 ms + 20 ms tolerance (typical)
For some codes, the processing time may be longer (see software
manual/»Engineer« online help for the Inverter Drive 8400).