E84AYCEC communication manual (Ethernet POWERLINK)
Parameter reference
Parameters of the communication module
68 L EDS84AYCEC EN 3.0 - 09/2012
C13028
The describing bit field has the following structure:
Parameter | Name:
C13028 | 0x1F81 Node Assignment CN
Data type: UNSIGNED_32
Index: 11547
d
= 2D1B
h
The code declares the controlled nodes 1 ... 100 and their properties.
Value is bit-coded:
Bit 0 ... 31 see below
Subcodes Lenze setting Info
C13028/1 0
... ..
C13028/100 0
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Bit Value Description
0 (LSB) 0 EPL node with this ID does not exist.
1 EPL node with this ID exists.
1 0 EPL node with this ID is not a controlled node.
1 EPL node with this ID is a controlled node.
2 0 On detection of a booting controlled node, the application will not be informed.
1 On detection of a booting controlled node, the application will be informed and the
controlled node will be started.
3 0 Optional controlled node
1 Obligatory controlled node
4 0 The managing node is allowed to send reset commands.
1 The managing node must not send any reset command.
5 0 Software version verification of the controlled node is not required.
1 Software version verification of the controlled node is required.
6 0 Automatic application software update is not allowed.
1 Automatic application software update is allowed.
7- Reserved / No function
8 0 Isochronously accessed controlled node
1 Asynchronously accessed controlled node (bit 9 is irrelevant)
9 0 Continuously accessed controlled node
1 Multiplex EPL nodes are supported.
10 0 No "Ethernet POWERLINK to standard Ethernet" router function.
1 Device can be used as an "Ethernet POWERLINK to standard Ethernet" router (router type 1).
11 0 No "Ethernet POWERLINK to fieldbus" router function.
1 The device can be used as an "Ethernet POWERLINK to fieldbus" router (router type 1).
12 0 The managing node does not send any PRes frames
1 The managing node sends PRes frames
13 ... 30 - Reserved / No function
31 (MSB) 0 Bits 0 ... 30 inhibited
1 Bits 0 ... 30 enabled
Seitenansicht 67
1 2 ... 63 64 65 66 67 68 69 70 71 72 73 ... 88 89

Kommentare zu diesen Handbüchern

Keine Kommentare