Seitenansicht 13
9400 Technology applications | Actuator – torque
Parameter setting & configuration
Torque setpoint conditioning
14 L EDS94TA10020xxxx EN 1.1 - 10/2008
4.4 Torque setpoint conditioning
[4-2] Torque setpoint conditioning (schematic diagram)
The torque setpoint is defined in the Lenze setting via the analog input 1 and take place in
both directions (bipolar) and accordingly the drive acts in a driving or braking manner.
r Parameter setting: Application parameters tab dialog level Overview
M
Gain Invert setpoint
LS_Torque...
M
Torque
setpoint
DI2DI3
OUT
IN
Ramp generator
Status
machine
(basic drive
functions)
Torque setpoint
AIN1
v
F
Parameter Lenze setting
Value Unit
C03002 Setpoint gain 100.00 %
Setpoint inputs of the function Signal configuration
Lenze setting Setpoint input (Multiplexer parameters)
AIN 1 Torque setpoint C03000