Function library
Function blocks
3.2.43 Motor potentiometer (MPOT)
3−126
l
EDSVS9332S−EXT EN 2.0
Tir
Tir
Tir
Tif
MPOT1−UP
MPOT1−DOWN
C0260
C0261
0
+
MPOT1−OUT
Fig. 3−108 Control signals of the motor potentiometer
In addition to the digital signals MPOT1−UP and MPOT1−DOWN another digital input exists
(MPOT1−INACT). The input MPOT1−INACT is used to activate or deactivate the motor potentiometer
function. Logic 1 at this input deactivates the motor potentiometer function. The input
MPOT1−INACT has priority over the inputs MPOT1−UP and MPOT1−DOWN.
When the motor potentiometer is deactivated, the motor potentiometer output (MPOT1−OUT)
follows the function set under C0264. The following functions can be set under C0264: