Function library
Function blocks
3.2.62 Storage block (STORE)
3−172
l
EDSVS9332S−EXT EN 2.0
Name LenzeListCFGDIS formatDISType
STORE1−ACT ph Outputs the currently integrated value
STORE1−PH1 ph Outputs the last value stored by X5/E5
STORE1−PH2 ph Outputs the last but one value stored by
X5/E5
STORE1−PHDIFF ph Outputs the difference of STORE1−PH1 and
STORE1−PH2
STORE1−TP−INH d HIGH = triggering via TP input E5 has been
done. For another triggering a positive edge
must be activated at the input
STORE1−ENTP.
C 1 2 2 3 / 1
S T O R E 2 - R E S E T
C 1 2 2 0 / 1
C 1 2 2 3 / 2
S T O R E 2 - E N T P
C 1 2 2 0 / 2
> 1
_
R
D
1
1
0
T P E i n g a n g E 4
0
R e g 1
R
C
R e g 2
R
C
S T O R E 2 - P H 1
S T O R E 2 - P H 2
S T O R E 2 - A C T
S T O R E 2 - T P - I N H
S T O R E 2
M C T R L - P H I - A C T
Fig. 3−161 Storage block (STORE2)
Signal
Source Note
Name Type DIS DIS format CFG List Lenze
STORE2−RESET d C1223/1 bin C1220/1 2 1000 HIGH = resets all functions
STORE2−ENTP d C1223/2 bin C1220/2 2 1000 HIGH = enables the triggering via the
TP input E4 free
STORE2−ACT ph Outputs the currently integrated value
STORE2−PH1 ph Outputs the last value stored by X5/E5
STORE2−PH2 ph Outputs the last but one value stored by
X5/E5
STORE2−TP−INH d HIGH = triggering via TP input E4 has been
done. For another triggering a positive edge
must be activated at the input
STORE1−ENTP.
Function
l STORE1 control via TP input E5
l Storing STORE1 phase signal
l Storing STORE2 phase signal