Drive PLC Developer Studio
Working with projects and objects
6-23
l
DDS EN 2.3
QSP Trip/CINH Warning
Event during
program processing
Response of the automation system
PLC stop, breakpoint Fail QSP is activated
Code C168, subcode 1
Error entry: none
CINH is activated
Code C168, subcode 1
Error entry: none
Motor continues running
Code C168, subcode 1
Error entry: none
Task overflo w Fail QSP is activated
Code C168, subcode 1
Error entry: Task overflow
CINH is activated
Code C168, subcode 1
Error entry: Task overflow
Motor continues running
Code C168, subcode 1
Error entry: none
Drive PLC
Automation system without drive function
Note!
The configuration of the digital outputs
remains unchanged with the extension modules.
remains unchanged with the Drive PLC.
QSP Trip/CINH Warning
Event during
program processing
Response of the automation system
PLC stop, breakpoint CINH is activated
Code C168, subcode 1
Error entry: none
Motor continues running
Code C168, subcode 1
Error entry: none
Task overflo w CINH is activated
Code C168, subcode 1
Error entry: Task overflow
Motor continues running
Code C168, subcode 1
Error entry: none