Drive PLC Developer Studio
Visualization
9-20
l
DDS EN 2.3
• A semicolon ”;” must be entered into the instruction part.
• Create a new visualisation with the name Screen1 and insert a rectangle with
InsertWRectangle.
• Mark the rectangle and open the configuration dialog with ExtrasW Configure.
In the category
Te xt
, input field content, enter the ”variable value”. The other options remain
unchanged.
• In the category
Variab les
, input field Textdisplay, enter ”$Ref$”. Placeholders are enclosed
by the $ signs. The signs must be represented.
• Confirm the dialog with OK.
• Re-mark the rectangle. Open the dialog box
Placeholder: set possible replacements
with
ExtrasWList of Placeholders complete the dialog box, and confirm with OK.
Placeholder Elementnumber Replacements
Ref 0 PLC_PRG.nVar10,PL C_ PRG.nVar20
• Create another visualisation with the name Screen2.
• The visualisation Screen2 must be active. Insert a visualisation reference. Execute the menu
command InsertWVisualisation and draw a rectangle in the visualisation Screen2. The dialog
box
Select Visualization
is displayed Select Screen1 and confirm with OK.
• Mark the entire reference and open the configuration dialog. In the category
Visualization
(Screen1) press the button Placeholder. Select
PLC_PRG.nVar20.
from the replacements
and confirm with OK.
• In the category
Visualization
(Screen1) only mark the control boxes Isotropic and Clip and
confirm with OK.
• Store the program with a suitable name and log in.
9.3.2.1 Group
Icon: - Menu: ExtrasWGroup Keyboard: -
Tip!
Group allows several elements to be moved simultaneously without affecting the distances
in-between.
How to group
• Select the elements to be grouped.
• Select ExtrasWGroup.
• Edit group (move, delete).
• Once the elements have been edited completely, the conglomerate can be ungrouped with
ExtrasWBreak up group.