Drive PLC Developer Studio
Editors
7-24
l
DDS EN 2.3
7.3.2.1 Configuring the monitoring window
Icon: - Menu: ExtrasWMonitoring options Keyboard: -
Use this command to configure the monitoring window.
In online mode, the text editor window is vertically split in two.
• Normal program text is shown on the left.
• Variables and their respective values are shown on the right.
Open the dialog box
Monitoring options
to effect the following settings:
• Width of monitor window (in percent).
• Distance between two monitoring variables in a line.
Distance 1 corresponds to one pixel in the selected resolution.
7.3.3 Breakpoint positions
Breakpoint positions are all program locations where variable values can change or program flow
branches.
• As the DDS internally combines several IL lines into one C code line, it is not possible to set
breakpoints in every line.
• Exception: Function calls:
Breakpoints must be set in the functions as necessary.
Possible breakpoint positions are identified with a dark grey line number field:
W
W
W
W
W
W
W
Instruction list editor
The following breakpoint positions are possible in the instruction list editor:
• At the beginning of an organization unit
• On every LD, LDN (or if an LD is set directly behind a label, on this label)
• At every JMP, JMPC, JMPCN
• At every label
• At every CAL, CALC, CALCN
• At every RET, RETC, RETCN
• At the end of the organization unit