Drive PLC Developer Studio
Editors
7-24
l
DDS EN 2.3
7.3.2.1 Configuring the monitoring window
Icon: - Menu: ExtrasWMonitoring options Keyboard: -
Use this command to configure the monitoring window.
In online mode, the text editor window is vertically split in two.
Normal program text is shown on the left.
Variables and their respective values are shown on the right.
Open the dialog box
Monitoring options
to effect the following settings:
Width of monitor window (in percent).
Distance between two monitoring variables in a line.
Distance 1 corresponds to one pixel in the selected resolution.
7.3.3 Breakpoint positions
Breakpoint positions are all program locations where variable values can change or program flow
branches.
As the DDS internally combines several IL lines into one C code line, it is not possible to set
breakpoints in every line.
Exception: Function calls:
Breakpoints must be set in the functions as necessary.
Possible breakpoint positions are identified with a dark grey line number field:
W
W
W
W
W
W
W
Instruction list editor
The following breakpoint positions are possible in the instruction list editor:
At the beginning of an organization unit
On every LD, LDN (or if an LD is set directly behind a label, on this label)
At every JMP, JMPC, JMPCN
At every label
At every CAL, CALC, CALCN
At every RET, RETC, RETCN
At the end of the organization unit
Show/Hide Bookmarks