DDS EN 2.3
No. Possible remedyCause
3163 Unknown reference type in library <Name>
(Icon <Name>, Class <Name>, Type <Name>)
The .obj file contains a reference type the code generator cannot resolve.
Check the C compiler settings.
3200 <Name> (%d): Logical expression too complex. The temporary memory of the automation system is insufficient to cope with t he size of the
expression.
Divide the expression into several part expressions with assignments to intermediate
variables.
3201 <Name> (<Network>): A network may return a maximum
of 512 byte code.
Internal jumps cannot be resolved.
Activate the option Use 16 bit jump offsets in the 68k target settings.
3202 Stack overflow on nested string/array/structure function
calls.
You are using a nested form CONCAT(x, f(i)) function call. This may lead to data loss. Split the
call into two expressions.
3203 Assignment too complex (too many address registers
required)
Split the assignment.
3204 Ajumpisinexcessof32kbytes. Jump distances must not exceed 32767 bytes.
3205 Internal error: Too many constant strings A maximum of 3000 string constants may be used within one organization unit.
3206 Function block too large A function block may return a maximum of 32767 bytes code.
3207 A rray optimization
Unsuccessful array access optimization.
A function was called within the index computation.
3208 Conversion not implemented You are using a conversion function that is not implemented for the current code generator.
3209 Operator not implemented You are using an operator that is not implemented for this data type in the current code
generator: MIN(string1,string2).
3210 Function <Name> not found You are calling a function that does not exist within the project.
3211 String variable used too often A string-type variable must only be used ten times in an expression with the 68K code
generator .
3250 Real not supported on 8 bit controller. The automation system is currently not supported.
3251 Date-of-day types not supported on 8 bit controller. The automation system is currently not supported.
3252 Stacksizeinexcessof%ldbytes. The automation system is currently not supported.
3253 Hex file not found: <Name> The automation system is currently not supported.
3254 Call of an external library function could not be resolved. The automation system is currently not supported.
3400 Error on access variable import. The .exp file contains an incorrect access variable section.
3401 Error on Configuration variable import. The .exp file contains an incorrect configuration variable section.
3402 Error on global variable import. The .exp file contains an incorrect global variable section.
3403 <Name> could not be imported. The section in the .exp file for the specified object is incorrect.
3404 Error on Configuration Task import. The section in the .exp file for the Configuration T ask is incorrect.
3405 Error on PLC configuration import. The section in the .exp file for the PLC configuration is incorrect.
3406 Tw o steps named <Name>.
The second step was not imported.
The SFC organization unit section contained in the .exp file includes two steps with identical
names. Rename one of the steps in the export file.
3407 Input step <Name> not found The named step is missing in the .exp file.
3408 Subsequent step <Name> not found The named step is missing in the .exp file.
3409 No subsequent transition for step <Name> A transition requiring the named step as the entry step, is missing in the .exp file.
3410 No subsequent step for transition <Name> A step requiring the named transition is missing in the .exp file.
3411 Step <Name> cannot be accessed from Init Step The link between the named step and the Init Step is missing in the .exp file.
3450 PDO<Name>: <Module name> <Configuration dialog
name> <PDO Name> COB-Id missing!
Click the button Properties in the configuration dialog <Configuration dialog name> of
module <Module name> and enter a COB ID for PDO <PDO Name>.
3451 Loading error: EDS file <Name> could not be found, but is
used in the configuration!
The device file required for CAN configuration may possibly not be available in the correct
directory. Check the directory entry for configuration files in Project
WOptions category
Directories.
3452 The module <Name> could not be generated! The device file for module <Name> no longer suits the current configuration. It may have
been changed since the original configuration, or be corrupted.
3453 Channel <Name> could not be generated! The device file for channel <Name> no longer suits the current configuration. It may have
been changed since the original configuration, or be corrupted.
3454 The address <Name> references an assigned memory
location!
You have activated the option Check for overlapping addresses in dialog Settings of the
PLC configuration, and an overlap was found. Note that the range check is based on the size
resulting from the module data t ype, and not the value in the entry Size in the configuration
file!
3455 Loading error: GSD file <Name> could not be found, but is
used in the configuration!
The device file required for Profibus configuration may possibly not be available in the
correct directory. Refer entry for configuration files in Project
WOptions category
Directories.
3456 The Profibus device <Name> could not be generated! The device file for device <Name> no longer suits the current configuration. It may have
been changed since the original configuration, or be corrupted.
3457 Incorrect module description: <Name>! Check the device file pertaining to the module.
3500 No VAR_CONFIG for <Name> Insert a declaration for the named variable in the global variable list with
Variable_Configuration. Resources
WGlobal_Variables ^ 8-2