EDSMF2133IB EN 5.0
How to read the code table
Column Meaning
Code
(Lenze) code
l The parameters of a configurable code marked with an asterisk (<Code>*) can only be accessed
via the communication module.
l The value of a configurable code marked with a double asterisk (<Code>**) is not transmitted
with the parameter set transfer.
Subcode Subcode
Name Designation of the Lenze code
Index Index under which the parameter is addressed.
Lenze
Lenze setting of the code
g Display code
Configuration of this code is not possible.
Values
Fixed values determined by Lenze (selection list) or a value range:
Minimum value [Smallest increment/unit] Maximum value
Access R = read access (reading permitted)
W = write access (writing permitted)
Data type l FIX32: 32−bit value with sign; decimal with 4 decimal positions
l U16: 2 bytes bit−coded
l U32: 4 bytes bit−coded
l VS: visible string, character string with defined length