Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37 Bedienungsanleitung Seite 469

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 679
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 468
L Firmware 1.37 - 09/2006 469
9400 HighLine | Parameter setting & configuration
Diagnostics & error analysis
Error messages of the operating system
Motor: Calculated mutual inductance unrealistic [0x007b0002]
Motor data is inconsistent [0x007b0003]
Motor: Phase resistance is too high [0x007b0004]
Motor: Device current is too low for rated magnetisation [0x007b0006]
Motor: Rated current < rated magnetisation current [0x007b0007]
Motor: Calculated rotor resistance unrealistic [0x007b0009]
Motor: Calculated mutual inductance unrealistic [0x007b000a]
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning : Information
Cause Remedy
Faulty motor parameterisation. Check motor parameters.
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning : Information
Cause Remedy
Faulty motor parameterisation. Check motor parameters.
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning : Information
Cause Remedy
Faulty motor parameterisation. Check motor parameters.
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning : Information
Cause Remedy
Controller current is too low for rated magnetisation, i.e.
the controller cannot energise the motor sufficiently.
Check drive dimensioning.
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning : Information
Cause Remedy
Faulty motor parameterisation. Check motor parameters and setting of C00022.
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning : Information
Cause Remedy
Faulty motor parameterisation. Check motor parameters.
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning : Information
Cause Remedy
Faulty motor parameterisation. Check motor parameters.
Seitenansicht 468
1 2 ... 464 465 466 467 468 469 470 471 472 473 474 ... 678 679

Kommentare zu diesen Handbüchern