L Firmware 1.37 - 09/2006 503
9400 HighLine | Parameter setting & configuration
Diagnostics & error analysis
Error messages of the operating system
CAN module (MXI1): Heartbeat error index 4 [0x009e0003]
CAN module (MXI1): Heartbeat error index 5 [0x009e0004]
CAN module (MXI1): Heartbeat error index 6 [0x009e0005]
CAN module (MXI1): Heartbeat error index 7 [0x009e0006]
CAN module (MXI1): Heartbeat error index 8 [0x009e0007]
CAN module (MXI1): Heartbeat error index 9 [0x009e0008]
Response (Lenze setting printed in bold) Setting: C13613/4 (; Adjustable response)
: None System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information
Cause Remedy
CANopen communication module in MXI1: No heartbeat
telegram received from node 4.
See remedy for "Heartbeat error index 1".
Response (Lenze setting printed in bold) Setting: C13613/5 (; Adjustable response)
: None System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information
Cause Remedy
CANopen communication module in MXI1: No heartbeat
telegram received from node 5.
See remedy for "Heartbeat error index 1".
Response (Lenze setting printed in bold) Setting: C13613/6 (; Adjustable response)
: None System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information
Cause Remedy
CANopen communication module in MXI1: No heartbeat
telegram received from node 6.
See remedy for "Heartbeat error index 1".
Response (Lenze setting printed in bold) Setting: C13613/7 (; Adjustable response)
: None System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information
Cause Remedy
CANopen communication module in MXI1: No heartbeat
telegram received from node 7.
See remedy for "Heartbeat error index 1".
Response (Lenze setting printed in bold) Setting: C13613/8 (; Adjustable response)
: None System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information
Cause Remedy
CANopen communication module in MXI1: No heartbeat
telegram received from node 8.
See remedy for "Heartbeat error index 1".
Response (Lenze setting printed in bold) Setting: C13613/9 (; Adjustable response)
: None System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information
Cause Remedy
CANopen communication module in MXI1: No heartbeat
telegram received from node 9.
See remedy for "Heartbeat error index 1".