Braking operation
Braking o peration without additional measures
8
249
EDS84ASC552 EN 9.1
8 Braking operation
8.1 Braking operation without additional measures
DC injection brake DCB
To decelerate small masses, the ”DC injection brake DCB” function can be parameterised.
DC-injection braking enables a quick deceleration of the drive to standstill without the
need for an external brake resistor.
ƒ Code C00036 can be used to select the braking current.
ƒ The m aximum braking torque to be realised by the DC braking current amounts to
approx. 20 ... 30 % of the rated motor torque. It i s lower compared to braking action
in generator mode with external brake resistor.
ƒ Automatic DC-injection braking (Auto-DCB) improves the starting performance of
the motor when the operation mode without speed feedback is used.
Further information on the relevant parameters can be obtained from the software
manual.