
Parameter setting
6-8
BA2112EN
6.1.2 Unit control (C0009 = 11)
In the following the bit assignment of control and status word is under C0009 = 11:
6.1.2.1 Control word
Control word for 82XX and 8200 vector
820X 821x,822x
8200vector
Factory setting:
C0001=3 if C0007 < 52
Factory setting:
C001=3 if C0007 > 51
0
JOG1, JOG2, JOG3
00 = C0046 active
01 = JOG1 (C0037) active
10 = JOG2 (C0038) active
JOG1, JOG2, JOG3
00 = C0046 active
01 = JOG1 (C0037) active
10 = JOG2 (C0038) active
NSET1-JOG1/3
00 = C0046 active
01 = JOG1 (C0037) active
10 = JOG2 (C0038) active
11 = JOG3 (C0039) active
1
=
ac
e
=
ac
e
NSET1-JOG2/3
2 CW/CCW (CW rotation/CCW rotation)
0 = CW rotation
1 = CCW rotation
CW/CCW (CW rotation/CCW rotation)
0 = CW rotation
1 = CCW rotation
DCTRL1-CW/CCW
0 = not active
1=active
3 QSP (quick stop)
0 = QSP not active
1=QSPactive
QSP (quick stop)
0 = QSP not active
1=QSPactive
AIF-CTRL-QSP
0 = not active
1=active
4 Reserved RFG stop (stop of the ramp function
generator)
0 = RFG stop not active
1=RFGstopactive
NSET1-RFG1-STOP
0 = not active
1=active
5 Reserved RFG zero (deceleration along the T i f
ramp C0013)
0 = RFG zero not active
1=RFGzeroactive
NSET1-RFG1-0
0 = not active
1=active
6 Reserved UP function for motor potentiometer
0 = UP not active
1=UPactive
MPOT1- UP
0 = not active
1=active
The default setting (see below) is
accepted with setting C0007 > 51
se C0410 t
set
u
wn
7 Reserved DOWN function for motor
potentiometer
0 = DOWN not active
1 = DOWN active
MPOT1-DOWN
0 = not active
1=active
u
configurations.
8 Reserved Reserved Rese rved
9 Ctrl. inhibit (controller inhibit)
0 = controller not inhibited
1 = controller inhibited
Ctrl. inhibit (controller inhibit)
0 = controller not inhibited
1 = controller inhibited
AIF-CTRL-CINH
0 = not active
1=active
10 Reserved Reserved No function
11 Reserved TRIP reset
0 -> 1 = Edge from 0 to 1
AIF- CTRL- TRIP-RESET
0 -> 1 = Edge from 0 to 1
12 PAR1 (Parameter set changeover)
0 -> 1 = Parameter set
1 -> 0 = Parameter set
PAR1 (Parameter set changeover)
0 -> 1 = Parameter set
1 -> 0 = Parameter set
DCTRL1-PAR2/4
0 = not active
1=active
13 Reserved Reserved DCTRL1-PAR3/4
0 = not active
1=active
14 DC brake (DC injection brake)
0 = DC brake not active
1 = DC brake active
DC brake (DC injection brake)
0 = DC brake not active
1 = DC brake active
MCTRL1-DCB
0 = not active
1=active
15 Reserved Reserved Rese rved
Kommentare zu diesen Handbüchern