Parameter setting
6-17
BA2112EN
Signal configuration C0005 Bit 15
(AIF-CTRL.B15)
Bit 14
(AIF-CTRL.B1
4)
Bit 13
(AIF-CTRL.B13)
Bit 12
(AIF-CTRL.B12)
Bit 11
(AIF-CTRL.B7)
Bit 6
(AIF-CTRL.B5)
Bit 5
(AIF-CTRL.B4)
vector control 1xx3 / 2xx3 / 3xx3
/ 5xx3 / 10xx3
NSET- RFG- STOP
(RFG stop)
NSET- RFG- 0
(RFG ze ro)
Reserved DCTRL-PAR*1 DCTRL-PAR-
LOAD
NSET-TI*1 NSET-TI*2
vector control 4xx3 NSET- RFG- STOP
(RFG stop)
NSET- RFG- 0
(RFG ze ro)
Reserved DCTRL-PAR*1 DCTRL-PAR-
LOAD
NSET- JOG*1 NSET-JOG*2
vector control 6xx3 / 7xx3 / 8xx3
/ 9xx3
Reserved Reserved Reserved DCTRL-PAR*1 DCTRL-PAR-
LOAD
Reserved Re se rved
vector control 11xx3 Reserved Reserved Reserved Reserved Re se rve d Rese rved Re se rved
6.1.3.3 Status word
Bit Name Meaning
0 Readytoswitchon Controller status information
0 = Status lower than READYTOSWITCHON
1 = Status at least SWITCHED ON
1 Ready for operation Controller status information
0 = Status lower than READY FOR OPERATION
1 = Status at least READY FOR OPERATION
2 Operation enabled Controller status information
0 = Status lower than OPERATION ENABLED
1=StatusOPERATION ENABLED
3 Fault Controller status information
0 = No fault (TRIP))
1 = Fault (TRIP) occured
4 Voltage inhibited Information about command Voltage inhibit
0 = Command active
1 = Command not active
5 Quick stop Information about command QUICK STOP
0 = Command active
1 = Command not active
6 Switch-on inhibit Controller status information
0 = Status not SWITCH-ON INHIBIT
1=StatusSWITCH-ON INHIBIT
7 Wa r n i ng Collective warning
0=Nowarning
1=warning
8 Message Collective message. Automatic setting and resetting of pulse inhibit in the controller status OPERATION ENABLED. Reasons for
this can be undervoltage or overvoltage as well as overcurrent (clamp).
0 = No message
1 = Message (IMP)
9 Re mote 82xx, 821x, 822x, 8200 vector: Bus access right depends on Lenze parameter Operating mode (C0001)
0 = C0001
3
1 = C0001 = 3
93XX:
10 Setpoint reached Status of speed/frequency deviation
0=RFGon
RF G off
1 = RFGon = RFGoff
11 Limit value Status of the DRIVECOM speed limitation
always 0
12 Re se rved 820X, 821X, 822X: Reserved
8200 vector, 93XX: Mapping to bit C0150.B14
13 Re se rved 820X, 821x, 822x: Reserved
8200 vector: Mapping to bit C0150.B15
93XX: Mapping to bit C0150.B3
14 Manufacturer 820X, 821x, 822x: I max (current limit reached)
0 = Current limit not reached
1 = Current limit exceeded
8200 vector, 93XX: Mapping to bit C0150.B2
15 Manufacturer 820X, 821x, 822x: Q min (f d < dQmin )
0 = Q min not active
1=Qminactive
8200 vector, 93XX: Mapping to bit C0150.B5