Parameter setting
6-10
BA2112EN
6.1.2.2 Status word
Status word for 82XX and 8200 vector
820X 821x,822x 8200vector
Lenze setting
0 Rese rved Actual parameter set
0=Parameterset1or3active
1=Parameterset2or4active
DCTRL-PAR-B0
1 IMP (pulse inhibit)
0 = Pulses for power stage enabled
1 = Pulses for power stage inhibited
IMP (pulse inhibit)
0 = Pulses for power stage enabled
1 = Pulses for power stage inhibited
DCTRL1-IMP
2 I
max
(current limit reached)
0 = Current limit not reached
1 = current limit reached
I
max
(current limit reached)
0 = Current limit not reached
1 = current limit reached
MCTRL1-IMAX
3 Rese rved f
d
=f
dset
0=f
d
f
dset
1=f
d
=f
dset
MCTRL1-RFG1= NOUT
4 f
d
=f
dset
0=f
d
f
dset
1=f
d
=f
dset
RFG on = RFG off
0=RFGon
RF G off
1 = RFG on = RFG out
NSET1-RFG1-I= 0
5 Qmin (f
d
f
dQmin
)
0 = Qmin not active
1=Qminactive
Qmin (f
d
f
dQmin
)
0 = Qmin not active
1=Qminactive
PCTRL1-QMIN
6 f
d
= 0 (act. frequency = 0)
0=f
d
0
1=f
d
=0
f
d
= 0 (act. frequency = 0)
0=f
d
0
1=f
d
=0
DCTRL1-NOUT= 0
7 Ctrl. inhibit (controller inhibit)
0 = controller not inhibited
1 = controller inhibited
Ctrl. inhibit (controller inhibit)
0 = controller not inhibited
1 = controller inhibited
DCTRL1-CINH
8...11 Unit status
0 = No error
8 = Error active
Unit sta tus
0 = Controller initialization
1 = Switch on inhibit
3 = Operation inhibited
4 = Flying-restart circuit active
5 = DC brake active
6 = Operation enabled
7 = Message active
8 = Fault active
Unit sta tus
0 = Controller initialization
1 = Switch on inhibit
3 = Operation inhibited
4 = Flying-restart circuit active
5 = DC brake active
6 = Operation enabled
7 = Message active
8 = Fault active
12 Overtemperature warning ( ϑ
max
-10°C)
0=Nowarning
1=Warning
Overtemperature warning
0=Nowarning
1=Warning
DCTRL1-OH-WARN
13 U
Gmax
(DC-bus overvoltage)
0 = No overvoltage
1 = overvoltage
U
Gmax
(DC-bus overvoltage)
0 = No overvoltage
1 = overvoltage
DCTRL1-OV
14 Direction of rotation
0 = CW rotation
1 = CCW rotation
Direction of rotation
0 = CW rotation
1 = CCW rotation
DCTRL1-CCW
15 Ready for operation
0 = not ready for operation
1 = ready for operation
Ready for operation
0 = not ready for operation
1 = ready for operation
DCTRL1-RDY