EDS94TA10040xxxx EN 1.1 - 10/2008 L 57
9400 Technology applications | Synchronism with mark synchronisation
Parameter setting & configuration
Parameterisable function blocks
4.14.5 CompareTPDiffTool
4.14.6 ConversionShaftToTool
Is an instance of Function
L_TbCompare Mark synchronisation (setpoint):
Comparison of the determined TP difference and the TP limit parameterised in
C03851 for the status message "TP limit exceeded" via C03875.
Mark synchronisation (setpoint)
(C 39)
Parameter Possible settings Information
C03885 Comparison function
0 dnIn1 = dnIn2
1 dnIn1 > dnIn2 Lenze setting
2 dnIn1 < dnIn2
3 |dnIn1| = |dnIn2|
4 |dnIn1| > |dnIn2|
5 |dnIn1| < |dnIn2|
Is an instance of Function
L_LdSyncOperation Master value linking
Parameter Possible settings Information
C03715 Coupling of measuring systems X
and Y
0 Unit coupling
1 Cycle equality
2 Free coupling Lenze setting
C03716/1 String of digits User-defined unit X
•Read only
C03716/2 String of digits User-defined unit Y
•Read only
C03717/1 0.0000 214748.3647 Coupling factor X
• Initialisation: 0.0000
C03717/2 0.0000 214748.3647 Coupling factor Y
• Initialisation: 0.0000
C03718/1 0 unit 2147483647 Cycle X
•Read only
C03718/2 0 unit 2147483647 Cycle Y
•Read only
C03719 -214748.3647 unit 214748.3647 Position X at the input
•Display of the dnXPosIn_p input
signal in the real unit of the
machine.
C03720 -214748.3647 unit 214748.3647 Trimming X
• Display of input signal
dnXOffset_p in real unit of the
machine.