EDS94TA10040xxxx EN 1.1 - 10/2008 L 71
9400 Technology applications | Synchronism with mark synchronisation
Parameter setting & configuration
Parameterisable function blocks
C03977/1...4
(subcode 1 ... 4 ≡ profile no. 1 ... 4)
Value is bit-coded: Touch probe configuration
• The touch probe channels to be
used are selected by setting the
corresponding bits to "1".
Bit 0 TP channel 1, rising edge Digital input 1
Bit 1 TP channel 1, falling edge
Bit 2 TP channel 2, rising edge Digital input 2
Bit 3 TP channel 2, falling edge
Bit 4 TP channel 3, rising edge Digital input 3
Bit 5 TP channel 3, falling edge
Bit 6 TP channel 4, rising edge Digital input 4
Bit 7 TP channel 4, falling edge
Bit 8 TP channel 5, rising edge Digital input 5
Bit 9 TP channel 5, falling edge
Bit 10 TP channel 6, rising edge Digital input 6
Bit 11 TP channel 6, falling edge
Bit 12 TP channel 7, rising edge Digital input 7
Bit 13 TP channel 7, falling edge
Bit 14 TP channel 8, rising edge Digital input 8
Bit 15 TP channel 8, falling edge
Bit 16 TP channel 9 Motor encoder zero pulse
Bit 18 TP channel 10 Load encoder zero pulse
Bit 20 TP channel 11 DFIN zero pulse
Bit 22 TP channel 12 DFOUT zero pulse
C03978 "Teach" position
• For execution via parameter
channel.
0Ê1 The position applied at the input
dnTeachPos_p is saved in the profile
selected via the input
dwTeachProfileNumber.
C03979/1 String of digits Position unit
•Read only
C03979/2 String of digits Speed unit
•Read only
C03979/3 String of digits Acceleration unit
•Read only
C03980/1 -214748.3647 unit 214748.3647 External target position
• Display of input signal
dnExtPos_p in real unit of the
machine.
C03980/2 -214748.3647 unit 214748.3647 Teach position
• Display of input signal
dnTeachPos_p in real unit of the
machine.
C03981/1 0 4 Selected profile
• Display of input signal
dwProfileNumber.
C03981/2 04Selected teach profile
• Display of input signal
dwTeachProfileNumber.
Parameter Possible settings Information