PLC Designer V2.x| Lenze Application Samples
The L_SCB_CANBasic.lib library
L_SCB_GetVersion - transfer of the version
288 L 1.3 EN - 07/2012
17.7 L_SCB_GetVersion - transfer of the version
Outputs
17.8 L_SCB_ParRead - read parameter
This FB reads a parameter and provides the value read to the application via outputs
dnData ... bData.
Inputs
Identifier/data type Value/meaning
dwVersion
DWORD
Output version
Identifier/data type Information/possible settings
xExecute
BOOL
Trigger read request.
TRUE Start read request once.
FALSE Deactivate reading.
byNodeNumber
BYTE
Node number
xUseSecondSDO
BOOL
TRUE: Use second SDO channel
FALSE: Use first SDO channel (Lenze setting)
byMasterNumber
BYTE
Interface number (0...3)
wIndex
WORD
CANopen index (0x0 ... 0xFFFF)
bySubCode
BYTE
Subcode (0 ... 255)