1.3 EN - 07/2012 L 65
PLC Designer V2.x| Lenze Application Samples
Working with the sample projects
8400 HighLine - "LAS_40_INTF_Can_84HL_TabPos" sample project
8.2.4 Program structure in the »PLC Designer«
How to proceed:
1. In the »PLC Designer«, open the "LAS_40_INTF_Can_84HL_TabPos.pro" sample
project.
2. Load the project to the IPC and Go online.
8.2.4.1 Control configuration
The CAN master (ID = 0) is the control section of the system configuration
Below the CAN master the 8400 HighLine (CAN node ID = 5) is attached.
The 8400 HighLine is embedded in the form of a device-independent EDS file
(LenzeDrive_Can2_8Word).
Two PDOs for CAN-Input and CAN-Output are used, respectively.
The transmission mode is sync-controlled (10 ms).