Lenze PLC Designer V2.x Bedienungsanleitung Seite 331

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 336
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 330
1.3 EN - 07/2012 L 331
PLC Designer V2.x| Lenze Application Samples
The L_SSC_Scaling.lib library
L_SSC_UnitToPos - conversion block
20.21 L_SSC_UnitToPos - conversion block
This FB converts a position value specified in the real unit of the machine to an internal
position value on the basis of the machine parameters transmitted.
Inputs
Outputs
Identifier/data type Information/possible settings
diPosIn_e4
DINT
Position in [unit]
Selection in "e4" view (fixed point with four decimal positions)
scAxisData
SSC_Axis_logic
Machine parameters
Identifier/data type Information/possible settings
diPosOut_p
DINT
Position in [increments]
xLimit
BOOL
"Output signal is limited" status
TRUE: The output signal is limited to the representable value range
±214748.3647.
xError
BOOL
"Error" status signal
FALSE Conversion carried out without errors
TRUE Error during the conversion
Seitenansicht 330

Kommentare zu diesen Handbüchern

Keine Kommentare